The owner or operator of a new tank battery operated in conjunction with a petroleum production facility shall not place, store, or hold in a stationary tank or other container, if the tank battery has a storage capacity of 65,000 gallons or greater, any hydrocarbon liquid unless the tank or other container is equipped with:
A. a floating roof, consisting of an external floating roof, internal floating cover or covered floating roof, which is equipped with a closure seal or seals maintained in good repair to close the space between the roof or cover edge and tank wall; orB. a well-maintained vapor-recovery system consisting of:(1) a vapor-gathering system capable of collecting the organic compound vapors and gases discharged; and(2) a vapor-disposal system capable of collecting the organic vapor and gases so as to minimize their emission to the atmosphere; orC. any other device which is at least as effective to minimize vapor or gas loss to the atmosphere.N.M. Admin. Code § 20.2.38.112
11/30/95; 20.2.38.112 NMAC - Rn, 20 NMAC 2.38.112 10/31/02