Current through Register Vol. 36, No. 1, January 14, 2025
Section 19.15.7.33 - RESERVOIR PRESSURE REPORT (Form C-124)A. An operator shall file form C-124 to report bottom hole pressures as required under the provisions of 19.15.18.9 NMAC and applicable special pool orders.B. An operator shall state the name of the pool; the pool datum, if established; the name of the operator and lease; the well number; the wellhead elevation above sea level; the date of the test; the total time the well was shut in prior to the test, the subsurface temperature in degrees fahrenheit at the test depth; the depth in feet at which the operator made the subsurface pressure test; the observed pressure in psi gauge corrected for calibration and temperature; the corrected pressure computed from applying to the observed pressure the appropriate correction for difference in test depth and reservoir datum plane; and any other information required on form C-124.N.M. Admin. Code § 19.15.7.33
19.15.7.33 NMAC - Rp, 19.15.13.1125 NMAC, 12/1/08, Amended and Renumbered from 19.15.7.32 by New Mexico Register, Volume XXXII, Issue 10, May 25, 2021, eff. 5/25/2021