Table 1
Specific Ground Water Quality Criteria--Class II-A and Practical Quantitation Levels
Explanation of Terms: | ||
* | = | Ground water quality criteria and PQLs are expressed as micrograms per liter ([micro]g/L) unless otherwise noted. Table 1 criteria are all maximum values unless clearly indicated as a range for which the minimum value is to the left and the maximum value is to the right. |
PQL | = | Practical quantitation level as defined in N.J.A.C. 7:9C-1.4 |
CASRN | = | Chemical Abstracts System Registration Number |
NA | = | not available for this constituent. |
a | = | Asbestos criterion is measured in terms of fibers/liter longer than 10 micrometers (f/L >10 [micro]m) |
CU | = | Standard Cobalt Units |
b | = | Threshold Odor Number |
(Total) | means the concentration of metal in an unfiltered sample following treatment with hot dilute mineral acid (as defined in "Methods for Chemical Analysis of Water & Wastes," USEPA-600/4-79-020, March 1979) or other digestion defined by the analytical method. However samples that contain less than 1 nephelometric turbidity unit (NTU) and are properly preserved, may be directly analyzed without digestion. | |
m | = | Pursuant to prevailing Safe Drinking Water Act rules any positive result for fecal coliform is in violation of the MCL and is therefore an exceedance of the ground water quality criteria. |
Table 2 | |
INTERIM GENERIC GROUND WATER QUALITY CRITERIA | |
Interim Generic Criteria--Synthetic Organic Chemicals (SOCs) | |
Constituent | Criteria |
SOCs defined as carcinogens in N.J.A.C. 7:9C-1.4 | 5 [micro]g/l each |
lacking specific or interim specific criteria | 25 [micro]g/l total |
SOCs defined as non-carcinogens in N.J.A.C. 7:9C-1.4 | 100 [micro]g/l |
lacking specific or interim specific criteria | each 500 [micro]g/l |
total |
N.J. Admin. Code Tit. 7, ch. 9C, app APPENDIX