N.J. Admin. Code § 7:27-17.4

Current through Register Vol. 56, No. 24, December 18, 2024
Section 7:27-17.4 - Discharge of GROUP II toxic substances

The Department has determined that GROUP II TXS should be subject to at least reasonably available control technology requirements. Accordingly, requirements for the implementation of control measures, including, but not limited to, requirements for the installation and use of control apparatus, set forth at N.J.A.C. 7:27-16 and 23, apply with full force to GROUP II TXS until the Department amends this rule in response to anticipated EPA rule-making or otherwise. For example, pursuant to this subsection and N.J.A.C. 7:27-16.4(b), certain transfers of methylene chloride may be conducted only with either a vapor control apparatus that reduces by no less than 90 percent the concentration of methylene chloride in the air-vapor mixture displaced during the transfer, a floating roof, or certain types of vapor balance systems. For another example, pursuant to this subsection and N.J.A.C. 7:27-23.3, a lacquer may not contain more than 5.7 pounds per gallon of methylene chloride, nor may it contain more than 4.7 pounds of VOC together with one pound of methylene chloride.

N.J. Admin. Code § 7:27-17.4

Adopted by 50 N.J.R. 409(a), effective 1/16/2018