TABLE 9.1 | |||
Recommended Minimum Number and Location of Clearance Dust | |||
Samples for All Abatement and Interim Control Work | |||
Clearance Category | Category | Number and Location of | Number and Location of |
Description | Single-Surface Wipe Samples in Each Area * | Composite Wipe Samples | |
1 | Interior | Two dust samples from every | Three composite samples for |
treatments | room in dwelling (whether treated or untreated): | every batch of four rooms | |
(whether treated or untreated): | |||
. | .One interior window sill | One floor composite | |
or window | |||
trough, alternating | One interior window sill | ||
between rooms, | composite | ||
. | One floor . | One window trough composite | |
No containment within dwelling | AND | AND | |
. | For common areas, one for | .For common areas, one | |
every 2,000 ft< 2 > of a | floor subsample for every | ||
common area room floor (if present). | 2,000 ft< 2 > (if present); | ||
up to 8,000 ft< 2 > can be | |||
sampled for each composite. | |||
2 | Interior | Same as Category 1, but only | Same as Category 1, but only |
treatments | in every treated room | in every treated room | |
AND, | AND, | ||
One floor sample out- side | One floor sample outside the | ||
the containment area but | containment area but within | ||
within 10 feet of the airlock | 10 feet of the airlock to | ||
to determine the | determine the effectiveness | ||
effectiveness of the | of the containment system. | ||
containment system. This | (This extra single-surface | ||
extra single-surface sample | sample is recommended in 20 | ||
is recommended in 20 percent | percent of the treated | ||
of the treated dwellings in | dwellings in multifamily | ||
multifamily housing | housing | ||
and all single-family | and all single-family | ||
With contai | homes. | homes.) | |
nment | |||
(plastic | . | For Common Areas, one | .For Common Areas, one |
sheeting | floor sample for every | floor dunsample for every | |
as airlock | 2,000 ft< 2 > and one floor | 2,000 ft< 2 > (up to 8,000 | |
on doorsbe | sample outside containment. | ft< 2 > for each composite) | |
tween | and one floor sample | ||
treated | . | outside containment | |
and untrea | |||
ted areas) | |||
3 | Exterior | Two dust samples as follows: | Two dust samples as follows: |
treatments | |||
. | .At least one dust sample | One composite on a | |
on a horizontal surface in horizontal surface in part of the outdoor living | horizontal surface in part of the outdoor living area (e.g., a porch floor or entryway), and One window trough composite for every 4 floors where exterior work was performed, including lower floors where exterior work was not done, if present. | ||
of the outdoor living area | |||
(e.g., a porch floor or entryway), and | |||
. | .One window trough sample | ||
on each floor where exterior work was performed. An additional trough sample should be collected from a few lower floors to determine if troughs below the area were contaminated by the work above. | |||
4 | Soil Treatment | One sample from the | One sample from the |
entryway. | entryway. | ||
.... | |||
.... | |||
A room includes a hallway or a stairway. If no window is present, collect | |||
just one floor sample. When a closet is treated, the room to which it is | |||
attached should be tested. A closet is not considered to be a separate room. | |||
SOURCE: PRE-PUBLICATION COPY: Guidelines For The Evaluation And Control of | |||
Lead-Based Paint Hazards in Housing, The National Center for Lead-Safe | |||
Housing, February 1995. |
N.J. Admin. Code § 5:17-9.1
See: 33 N.J.R. 1807(a), 33 N.J.R. 3307(a).
Rewrote (f).