Composite piles include those consisting of two types of piles joined together. The maximum allowable load shall be that allowed for the component of lesser strength used to make up the full pile length. The connection or joint between the two components shall be constructed so as to prevent the separation of the upper and lower components during construction and thereafter. The details and methods of making joints shall be designed.
N.J. Admin. Code § 19:6-2.56