Current through Register Vol. 56, No. 21, November 4, 2024
Section 13:54-6.4 - Minimum requirements for installation of a tape, contact or invisible ray alarm system(a) The installation of a tape, contact or invisible ray alarm system must: 1. Completely protect all accessible windows, doors, transoms, skylights and other openings leading from the premises;2. Protect with contacts only, all movable accessible openings leading from the premises, and which provides one or more invisible rays or channels of radiation, with the minimum overall length of the rays or radiation equivalent to the longest dimensions of the area or areas to detect movement through the channel at a rate of one step per second; or3. Protect with contact only, all doors leading from the premises and provide a system of invisible radiation to all sections of the enclosed area so as to detect movement. The system shall respond to the movement of a person walking not more than four consecutive steps at a rate of one step per second.N.J. Admin. Code § 13:54-6.4