Current through Register Vol. 56, No. 24, December 18, 2024
Section 13:20-53C.6 - Shut-off valves(a) One manually-operated shut-off valve shall be secured directly to the tank vapor outlet with no intervening fitting other than the safety relief valve and shall be marked "VAPOR SHUT-OFF VALVE."(b) Another manually-operated shut-off valve shall be secured directly to the tank liquid outlet and shall be marked "LIQUID SHUT-OFF VALVE."(c) Automatic shut-off valves that are held open by electrical current may be used in lieu of manual shut-off valves at either the tank vapor port or tank liquid port, or both. An automatic shut-off valve shall be wired so that it shuts off when the ignition switch is in the "off" or "accessory" position and when engine vacuum or oil pressure is not present. N.J. Admin. Code § 13:20-53C.6