N.J. Admin. Code § 13:20-53A.2

Current through Register Vol. 56, No. 21, November 4, 2024
Section 13:20-53A.2 - Fuel supply container
(a) Each LPG fuel supply container shall be constructed, inspected, and permanently marked in accordance with 49 CFR § 393.69, incorporated herein by reference, as amended and supplemented, or the ASME Code provision.
(b) Fuel supply containers constructed to the United States Department of Transportation specifications shall have a minimum service pressure of 240 pounds per square inch.
(c) Fuel supply containers constructed to the ASME Code specifications shall have a minimum working pressure of 250 pounds per square inch.
(d) Each fuel supply container shall be equipped with an outage valve or a fixed liquid level gauge to indicate when the container is 80 percent full. A float gauge shall not be used to meet this requirement.
(e) Each fuel supply container shall have a fill valve that limits the amount of fuel that may be pumped into such container to 80 percent of the container capacity.

N.J. Admin. Code § 13:20-53A.2