Current through Register No. 50, December 12, 2024
Section Sep 603.01 - Minimum Requirements for Septic System Evaluation ReportsReports prepared by licensees pursuant to this chapter shall, at a minimum contain the following information:
(a) The client's name that is ordering the report;(b) The following information available off-site, provided by the owner or agent, if available prior to inspection: (1) Property location, including street address, tax map number, and lot number;(3) Research tax card, DES OneStop Data and Information, Online Searchable Database, and town files;(4) Type of use, whether residential or commercial;(5) Current use or vacant building;(6) State approval and plans;(7) Year the building was constructed;(8) Year the septic system was installed;(9) Whether a garbage disposal is present; (10) Whether a hot tub or a soaking tub is present;(11) Any water system conditioners backwashed into EDA;(12) Identification of basement bathrooms with injector pumps;(13) Pumping records if known; and(14) Whether any separated systems such as laundry or other disposal systems are present.(c) The following information obtained from the on-site evaluation: if the following information cannot be obtained or is pertinent the evaluator must state why or be provided by the owner or agent: (2) Whether the site differs from existing plans and town or state information;(3) Type of system found;(4) When digging, what was found, and how many holes;(5) Information relative to root infiltration;(6) The approximate size of the system;(7) Current weather conditions;(8) Information relative to any innovative technology used;(9) Whether the D-Box was evaluated;(10) Condition of the system;(12) The following information concerning the septic tank: a. The estimated size and type;b. Pumping schedule from owner;c. Whether baffles are present and what type;d. Whether the tank was pumped at time of inspection;f. Scum and sludge depths; h. Tank accessibility; andi. Whether effluent filter is present; (13) Whether there is a pump station present and, if so:a. Whether the pump is operational; andb. Whether any alarms are present;(14) Whether there is a municipal or observable onsite well and, for onsite wells, the well radius, distance to well if known;(15) Overall site condition, as evidenced by photos, sketches, or state approved septic plan(s);(16) A notation if no field is located;(17) Proprietary standards; and(18) If access to basement is available, check for gray matter effluent line;(d) The evaluator's license number;(e) A report of those systems and components that, in the professional opinion of the evaluator, are not functioning properly, are damaged, or are unsafe;(f) Any recommendations to correct, or monitor for future correction, deficiencies reported in Sep 603.01(b) or items needing further evaluation; and(g) An evaluator shall not make comments on the life of the system.N.H. Admin. Code § Sep 603.01