N.H. Admin. Code § Lab 1403.13

Current through Register No. 50, December 12, 2024
Section Lab 1403.13 - Concrete, Concrete Forms, and Shoring

The employer shall ensure compliance with the following requirements:

(a) Employees shall not work above vertically protruding reinforcing steel, unless it has been protected to eliminate the hazard of impalement;
(b) Powered and rotating-type concrete troweling machines that are manually guided shall be equipped with a deadman-type operating control; and
(c) Formwork and shoring shall safely support all loads imposed during concrete placement. Drawings or plans of jack layout, formwork, shoring, working decks, and scaffolding systems shall be available at the jobsite.

N.H. Admin. Code § Lab 1403.13

#4118 eff 8-22-86, EXPIRED: 8-22-92

New. #6684, eff 2-4-98, EXPIRED: 2-4-06

New. #8606, INTERIM, eff 4-12-06, EXPIRED 10-09-06 (formerly Lab 1403.14 )

New. #8796, eff 1-11-07

Amended by Volume XXXV Number 18, Filed May 7, 2015 , Proposed by #10809, Effective 4/9/2015, Expires4/9/2015.