Current through Register No. 50, December 12, 2024
Section Inst 603.13 - Installation Close-up and Finishing(a) Skirting shall be made out of weather resistant material. It shall not be attached in a manner that can cause water to be trapped between the siding and trim.(b) Ventilation shall be provided for the crawl space with skirting at a minimum of 1 ft 2 of free area for every 600 ft2. of house area floor.(c) Access openings not less than 18 inches in width and 24 inches in height and not less than 3 square feet shall exist so water supply and sewer drain connections located under the house are accessible for inspections. For the purpose of this section, openings shall include doors, hatches or removable panels.(d) Dryer vents, water heater overflow drains,air conditioning condensation drains shall pass through the skirting to the outside. They shall vent into the atmosphere to ensure moisture is carried beyond the perimeter of the house.N.H. Admin. Code § Inst 603.13
#8494, eff 12-24-05; ss by #10155, eff 4-14-12