Current through Register No. 50, December 12, 2024
Section He-P 4044.11 - Radiation Monitoring Requirements Each particle accelerator facility shall have available:
(a) Appropriate portable monitoring equipment which: (2) Has been calibrated for the appropriate radiations being produced at the facility;(3) Has been tested daily for proper operation;(4) Has been calibrated at intervals not to exceed one year;(5) Has been calibrated after each servicing; and(6) Has been calibrated after repair;(b) A radiation protection survey, performed and documented by a qualified expert specifically registered with DHHS/RHS pursuant to He-P 4040.06, which documents changes in shielding, operation, equipment, or occupancy of adjacent areas;(c) Continuous monitoring devices for all high radiation areas which are electrically independent of the accelerator control and safety interlock systems and are capable of providing a readout at the control panel;(d) An area monitor which has been calibrated at intervals not to exceed one year and after each servicing and repair;(e) Periodic surveys to determine the amount of airborne particulate radioactivity present in areas of airborne hazards if applicable;(f) Periodic smear surveys to determine the degree of contamination in target and other pertinent areas if applicable;(g) An area survey which is made in accordance with the written procedures established by a qualified expert, or the radiation safety officer of the particle accelerator facility; and(h) Records of: (1) Radiation protection surveys;(3) Instrumentation tests; andN.H. Admin. Code § He-P 4044.11
#6827, eff 8-6-98; ss by #8692, INTERIM, eff 7-27-06, EXPIRES: 2-2-07; ss by #8808, eff 1-24-07
Amended byVolume XXXV Number 14, Filed April 9, 2015, Proposed by #10804, Effective 3/26/2015, Expires3/26/2025.