Current through Register No. 50, December 12, 2024
Section He-P 4034.39 - Specific Requirements for Radiographic Personnel Performing Industrial Radiography(a) At a job site, the following shall be supplied by the licensee or registrant: (1) At least one operable, calibrated survey instrument for each exposure device or radiation machine in use;(2) A current whole body individual monitoring device such as: film badge, TLD, or OSL for each worker;(3) An operable, calibrated pocket dosimeter with a range of zero to 200 milliroentgens for each worker;(4) An operable, calibrated, alarming ratemeter for each worker; and(5) The appropriate barrier ropes and caution signs.(b) Each radiographer at a job site shall have on their person a valid certification ID card issued by a certifying entity.(c) Industrial radiographic operations shall not be performed if any of the items in He-P 4034.39(a) are not available at the job site or are inoperable.(d) During an inspection, DHHS/RHS shall terminate an operation if any of the items in He-P 4034.39(a) are not available or operable, or if the required number of radiographic personnel is not present.(e) Operations terminated under the conditions of He-P 4034.39(d) shall not be resumed until all required conditions are met.N.H. Admin. Code § He-P 4034.39
(See Revision Note at part heading for He-P 4034) #6942, eff 2-1-99; ss by #8800, INTERIM, eff 2-1-07, EXPIRED: 7-31-07
New. #8959, eff 8-7-07
Amended by Volume XXXV Number 49, Filed December 10, 2015, Proposed by #10983, Effective 11/24/2015, Expires11/24/2025.