Current through Register No. 50, December 12, 2024
Section Env-Wq 305.13 - Discharge Request Form: Applicant PortionThe applicant shall provide the following information on or with the applicant portion of the discharge request form:
(a) The name, street address, and mailing address of the indirect discharger;(b) The name, position, and daytime telephone number of a responsible individual at the indirect discharger, such as a plant manager, plant engineer, president, or vice president of the company, who has been authorized by the indirect discharger to certify the permit application as specified in Env-Wq 305.14(b);(c) The North American Industry Classification System (NAICS) code of the indirect discharger and, if available, the SIC code(s);(d) Whether the indirect discharger is subject to national categorical standards, and if so, which standards;(e) Information on the proposed flow, including the estimated average, minimum, maximum and total daily flow for domestic discharges and each process discharge and the time and duration of those discharges;(f) A schematic of the proposed pretreatment process;(g) The name, company, and license number of the chemical, civil, sanitary, or environmental professional engineer (PE) authorized to work in New Hampshire under RSA 310-A who prepared the treatment system plans and specifications, if plans and specifications are being submitted for review;(h) If applicable, plans, specifications, and operation and maintenance procedures for new or modified treatment facilities at the indirect discharger, stamped by the PE identified pursuant to (g), above;(i) A schematic diagram showing the production process, including the origin of each waste stream;(j) A list of pollutants expected to be present in the discharge and the anticipated quantity of each, based on: (1) Analyses of the waste stream(s) to be discharged, in which case test results shall be submitted with the discharge permit request; or(2) Knowledge of the process that produces the wastewater;(k) If pretreatment is proposed, whether as a BMP or control technique or technology, performance results of the pretreatment as determined by testing or by the manufacturer;(l) Information on the toxicity and treatability of the pollutants proposed to be discharged, as available from manufacturer's testing, safety, and data publications;(m) A map showing the location within the municipality of the indirect discharger with respect to the POTW;(n) A listing of all chemicals used at the indirect discharger that will be or could be discharged, such as production chemicals, degreasers, and cleaning solvents;(o) A description and location diagram of all sampling locations at the indirect discharger;(p) A brief narrative describing those measures taken or planned to reduce water usage and implement pollution prevention techniques, if any, such as:(2) Countercurrent rinses;(3) Recycling of non-contact cooling water;(4) Chemical substitutions; and(5) Pollutant source reduction; and(q) A list of all environmental permits held by or for the indirect discharger.N.H. Admin. Code § Env-Wq 305.13
(See Revision Note at part heading for Env-Wq 305) #10381, eff 8-1-13
Amended by Volume XLI Number 32, Filed August 12, 2021, Proposed by #13241, Effective 7/24/2021, Expires 7/24/2031