N.H. Admin. Code § Env-Wq 1613.03

Current through Register No. 49, December 5, 2024
Section Env-Wq 1613.03 - Criteria for Review

The department shall issue an EQ certification to the applicant if it determines that the information submitted demonstrates that the solids and filtrate:

(a) Is not a hazardous waste as defined in RSA 147-A:2, VII;
(b) Consistently meets the EQ pathogen and vector attraction requirements specified in the application;
(c) For solids, does not exceed the following concentrations, expressed as the total concentration on a dry weight basis:
(1) For arsenic, 32 mg/kg;
(2) For cadmium, 14 mg/kg;
(3) For chromium, 1000 mg/kg;
(4) For copper, 1500 mg/kg;
(5) For lead, 300 mg/kg;
(6) For mercury, 10 mg/kg;
(7) For molybdenum, 35 mg/kg;
(8) For nickel, 200 mg/kg;
(9) For selenium, 28 mg/kg; and
(10) For zinc, 2500 mg/kg;
(d) For filtrate, does not exceed the following concentrations:
(1) For arsenic, 0.4 mg/l;
(2) For cadmium, 0.2 mg/l;
(3) For chromium, 12.0 mg/l;
(4) For copper, 12.0 mg/l;
(5) For lead, 8.0 mg/l;
(6) For mercury, 0.2 mg/l;
(7) For molybdenum, 0.7 mg/l;
(8) For nickel, 4.0 mg/l;
(9) For selenium, 4.0 mg/l;
(10) For zinc, 20.0 mg/l; and
(11) For nitrate, 10.0 mg/l; and
(e) Is of sufficiently consistent quality such that for the constituents in (c) and (d) above, the mean concentration for data submitted under Env-Wq 1613.01(e) plus one standard deviation from the mean does not exceed 1.5 times the concentration specified in (c) or (d) above.

N.H. Admin. Code § Env-Wq 1613.03

#8458, eff 10-27-05 (see Revision Note at chapter heading); ss by #10466, eff 11-26-13