Current through Register No. 45, November 7, 2024
Section Env-Wq 1508.16 - Pretreatment Practices: Deep Sump Catch Basins Deep sump catch basins shall comply with the following:
(a) The contributing area shall not exceed 0.25 acres of impervious area;(b) The distance from the bottom of the outlet pipe to the bottom of the catch basin shall be at least 4 feet;(c) The diameter of the catch basin shall be at least 4 feet; and(d) A hooded outlet pipe shall be provided that extends at least one foot below the bottom of the outlet pipe.N.H. Admin. Code § Env-Wq 1508.16
(See Revision Note #1 at chapter heading for Env-Wq 1500) #9343, eff 1-1-09
Amended by Volume XXXVII Number 32, Filed August 10, 2017, Proposed by #12342, Effective 8/15/2017, Expires 8/15/2027.Amended by Number 41, Filed October 12, 2023, Proposed by #13758, Effective 9/28/2023, Expires 9/28/2033 (formerly Env-Wq 1508.15) (see Revision Note #4 at chapter heading for Env-Wq 1500).