Section Env-Or 606.16 - Design Plans and Construction Specifications(a) The design plans and construction specifications required pursuant to Env-Or 606.15(b) shall include the following, as applicable: (1) A description of the purpose and function of the remedial treatment system or source removal project;(2) A list of applicable design criteria for the remedial treatment system or source removal project including, but not limited to:b. Physical properties of the soil and aquifer;d. Subsurface obstacles, barriers, or both;f. Air and water discharge permit requirements;g. Remedial treatment system flow rates; andh. Remedial treatment system efficiency;(3) Remedial treatment system performance standards;(4) Characteristics, quantities, and locations of environmental media and contaminants to be treated or removed;(5) Expected waste products that will be generated and their means of disposal;(6) Pilot test results used in the preparation of the design; and(7) Manufacturer's data describing the equipment in the design.(b) Construction plans and specifications required pursuant to Env-Or 606.15(b) shall provide sufficient detail for construction of the remedial system or source removal project.(c) The design plans and construction specifications prepared pursuant to this section shall be dated, signed, and sealed by the engineer of record.N.H. Admin. Code § Env-Or 606.16
(See Revision Note at chapter heading for Env-Or 600) #8812, eff 2-1-07
Amended by Volume XXXV Number 23, Filed June 11, 2015 , Proposed by #10831, Effective 6/1/2015, Expires6/1/2025.