The owner or operator of an existing OSWI unit using a wet scrubber to control emissions shall comply with the operating practices specified in table 4304-1, below:
Table 4304-1: Operating Practices for Existing OSWI Units
Operating Parameters | Operating Limits | Continuous Monitoring Recording Times |
Charge rate | Maximum charge rate | Every hour |
Pressure drop across the wet scrubber, or amperage to the wet scrubber | Minimum pressure drop or amperage | Every 15 minutes |
Scrubber liquor flow rate | Minimum flow rate | Every 15 minutes |
Scrubber liquor pH | Minimum pH | Every 15 minutes |
N.H. Admin. Code § Env-A 4304.01
#8787, eff 1-5-07