Current through Register No. 50, December 12, 2024
Section Env-A 2302.01 - Emission Standards Applicable to Cyclone-Firing, Wet-Bottom Boilers(a) For any cyclone-firing, wet-bottom boiler subject to this chapter whose maximum heat input rate is less than or equal to 3,000 million BTUs per hour, the following emission rates shall apply: (1) SO2 emissions shall not exceed limitations specified in permit conditions established in accordance with Env-A 600, as recorded by a continuous emissions monitoring system (CEMS) as specified in Env-A 2303;(2) NOx emissions shall not exceed the limitations for wet-bottom utility boilers specified in Env-A 1303, as recorded by a CEMS as specified in Env-A 2303; and(3) TSP emissions shall not exceed 0.08 pound (lb.) per million BTUs, demonstrated by completion of periodic stack tests as specified in Env-A 2304.01(b) on the outlet side of the final emission control device.(b) For any cyclone-firing, wet-bottom boiler subject to this chapter whose maximum heat input rate is greater than 3,000 million BTUs per hour, the following emission rates shall apply:(1) SO2 emissions shall not exceed limitations specified in permit conditions established in accordance with Env-A 600, as recorded by a CEMS as specified in Env-A 2303;(2) NOx emissions shall not exceed the limitations for wet-bottom utility boilers specified in Env-A 1303, as recorded by a CEMS as specified in Env-A 2303; and(3) TSP emissions shall not exceed 0.08 lb. per million BTUs, demonstrated by completion of periodic stack tests as specified in Env-A 2304.01(b) on the outlet side of the final emission control device.N.H. Admin. Code § Env-A 2302.01
Amended by Volume XXXIX Number 19, Filed May 9, 2019, Proposed by #12766, Effective 5/1/2019, Expires 5/1/2029.Amended by Volume XLI Number 36, Filed September 9, 2021, Proposed by #13254, Effective 8/25/2021, Expires 8/25/2031.