Section Env-A 1803.05 - Compliance Inspections and Production of Records(a) Upon the request of the department, in conjunction with any inspection pursuant to RSA 141-E:8 or RSA 141-E:13, building owners or managers shall review building records for references to ACM used in construction or repairs and provide all information found to the department in writing.(b) If, during an inspection pursuant to RSA 141-E:8 or RSA 141-E:13, the authorized representative observes material suspected of being friable ACM, the authorized representative shall touch or rub the suspect material to determine friability.(c) If the suspect material is friable, the authorized representative shall: (1) Collect 3 bulk samples of the material;(2) Collect air samples; and(3) Have the samples analyzed by an asbestos analysis service which meets the criteria set forth under Env-A 1809.(d) The department shall provide a copy of the analytical results to the O/O, building manager, or other interested parties upon receipt of a written request.N.H. Admin. Code § Env-A 1803.05
(See Revision Note at chapter heading for Env-A 1800) #9298, eff 10-21-08
Amended by Volume XXXVII Number 19, Filed May 11, 2017, Proposed by #12172, Effective 5/5/2017, Expires 5/5/2027.