N.H. Admin. Code § Env-A 1305.12

Current through Register No. 50, December 12, 2024
Section Env-A 1305.12 - RACT Requirements: Industrial Boilers Firing Oil and/or Gas

For boilers that are subject to Env-A 1305.09(a) and fire, or are capable of firing, oil or gas, or any combination thereof, the NOx RACT requirements shall be as follows:

(a) For tangential or face-fired boilers when firing oil exclusively:
(1) An emission limit of 0.30 lb. per million Btu, based on a 24-hour calendar day average; or
(2) Implement NOx RACT control technology as specified in Env-A 1305.09(b); and
(b) For tangential or face-fired boilers when firing gas, or any combination of oil and gas, an emission limit of 0.25 lb. per million Btu based on a 24-hour calendar day average.

N.H. Admin. Code § Env-A 1305.12

(See Revision Note at chapter heading for Env-A 1300) #9803, eff 10-31-10

Amended by Volume XXXVIII Number 32, Filed August 9, 2018, Proposed by #12584, Effective 8/15/2018, Expires 8/15/2028.