Current through Register No. 45, November 7, 2024
Section Env-A 1219.07 - Work Practice Standards(a) All resin and gel coat mixing containers with a capacity equal to or greater than 208 liters, equivalent to 55 gallons, including those used for on-site mixing of putties and polyputties, shall have a cover with no visible gaps in place at all times, except when material is being manually added to or removed from a container, or when mixing or pumping equipment is being placed in or removed from a container.(b) VOC cleaning solvents for routine application equipment cleaning shall contain no more than 5 percent VOC, by weight, or have a composite vapor pressure of no more than 0.50 mm Hg at 68 ºF.(c) Only non-VOC solvents shall be used to remove cured resin and gel coat from application equipment.N.H. Admin. Code § Env-A 1219.07
(See Revision Note at chapter heading for Env-A 1200) #9933, eff 6-1-11
Amended by Volume XXXIX Number 46, Filed November 14, 2019, Proposed by #12899, Effective 10/17/2019, Expires 10/17/2029