N.H. Admin. Code § Env-A 1213.08

Current through Register No. 50, December 12, 2024
Section Env-A 1213.08 - Leak Inspection and Maintenance Plan for Wood Furniture Coating Sources

Each owner or operator of a wood furniture coating source shall prepare, maintain, and implement a leak inspection and maintenance plan that contains the following:

(a) A minimum visual inspection frequency of once per month for all equipment used to transfer or apply finishing materials or organic solvents;
(b) An inspection schedule;
(c) Methods for documenting the date and results of each inspection and any repairs that were made and any maintenance that was performed; and
(d) The timeframe between identifying a leak and repairing the leak, in accordance with the following schedule:
(1) The first repair attempt, such as tightening of packing glands, shall be made no later than 5 working days after the leak is initially detected; and
(2) Final repairs shall be made within the following time periods:
a. If the leaking equipment is to be replaced by a new purchase, not later than 90 calendar days after initial leak detection; or
b. If the leaking equipment is not to be replaced by a new purchase, not later than 15 working days after initial leak detection.

N.H. Admin. Code § Env-A 1213.08

(See Revision Note at chapter heading for Env-A 1200) #9933, eff 6-1-11

Amended by Volume XXXIX Number 46, Filed November 14, 2019, Proposed by #12899, Effective 10/17/2019, Expires 10/17/2029