Current through November 25, 2024
Section 704.934 - Preparation, contents and submission of demand side plan; annual analyses regarding programs for energy efficiency and conservation1. As part of its resource plan, a utility shall submit a demand side plan that is cost effective as a whole.2. The demand side plan must include:(a) An identification of end-uses for programs for energy efficiency and conservation.(b) An assessment of savings attributable to technically feasible programs for energy efficiency and conservation, as determined by the utility. The programs must be ranked in a list according to the level of savings in energy or reduction in demand, or both.(c) An assessment of technically feasible programs to determine which will produce benefits in peak demand or energy consumption. The utility shall estimate the cost of each such program. The methods used for the assessment must be stated in detail, specifically listing the data and assumptions considered in the assessment.(d) An energy efficiency plan which complies with the requirements of NRS 704.7836, and which includes any additional goals for energy savings established by the Commission.3. In creating its demand side plan, a utility shall consider the impact of applicable new technologies on current and future energy efficiency and conservation options. The consideration of new technologies must include, without limitation, consideration of the potential impact of advances in digital technology and computer information systems.4. A utility shall include in its demand side plan an energy efficiency program for residential customers which reduces the consumption of electricity or any fossil fuel. The energy efficiency program must include, without limitation, the use of new solar thermal energy sources.5. The demand side plan must provide a list of the programs for which the utility is requesting the approval of the Commission. The list must include, without limitation:(a) An estimate of the reduction in the peak demand and energy consumption that would result from each proposed program, in kilowatt-hours and kilowatts saved. The programs must be listed according to their expected savings and their contribution to a reduction in peak demand and energy consumption based upon realistic estimates of the penetration of the market and the average life of the programs.(b) An assessment of the costs of each proposed program and the savings produced by the program. If the program can be relied upon to reduce peak demand on a firm basis, the assessment must include the savings in the costs of transmission and distribution.(c) An assessment of the impact on the utility's load shapes of each proposed and existing program for energy efficiency and conservation.(d) If a program is an educational program, the projected expenses of the utility for the educational program.6. For any energy efficiency or conservation program which reduces the consumption of electricity or any fossil fuel, a utility shall include in its demand side plan a complete life-cycle analysis of the costs and benefits of the program using at least one standard test of cost effectiveness that accounts for the nonenergy benefits of the program.7. The utility shall include with its demand side plan a report on the status of all programs for energy efficiency and conservation that have been approved by the Commission. The report must include tables for each such program showing, for each year, the planned and achieved reduction in kilowatt-hours, the reduction in kilowatts and the cost of the program.8. Not less than 10 percent of the total expenditures related to energy efficiency and conservation programs in the demand side plan must be directed to energy efficiency measures for customers of the electric utility in low-income households and residential customers and public schools in historically underserved communities through both targeted programs and programs directed at residential customers and public schools in general.9. On or before July 1 of each year following the filing of its resource plan, the utility shall file with the Commission a copy of the complete analysis that the utility used in determining for the upcoming year which energy efficiency and conservation programs are to be continued and which programs are to be cancelled. Within 180 days after the analysis is filed, the Commission will accept the analysis as filed, accept the analysis with modification or reject the analysis.10. As used in this section: (a) "Energy efficiency and conservation program" has the meaning ascribed to it in NRS 704.7366.(b) "Energy savings" has the meaning ascribed to it in NRS 704.7834.(c) "Historically underserved community" has the meaning ascribed to it in NRS 704.78343.(d) "New solar thermal energy sources" means energy sources which are installed after the effective date of the utility's energy efficiency program and which reduce the consumption of electricity or any fossil fuel by using solar radiation to heat water or to provide space heating or cooling.Nev. Admin. Code § 704.934
Added to NAC by Pub. Service Comm'n, eff. 6-7-84; A 2-18-88; 11-19-93; A by Pub. Utilities Comm'n by R004-04, 5-25-2004; R162-07, 6-17-2008; R042-10, 7-22-2010; A by R055-18A, eff. 6/13/2019; A by R005-22A, eff. 9/16/2022NRS 703.025, 704.210, 704.741, 704.7836