Current through September 17, 2024
The loadout facility will be designed and constructed pursuant to the following minimum requirements:
002.01 Constructed of concrete, asphalt or other impermeable material. After June 27, 2011, the loadout facility may not be constructed of asphalt;002.02 Constructed to withstand the weight of vehicles which will be on the loadout facility;002.03 Sized to contain a minimum of 1,800 gallons or 1.5 times the largest container, whichever is smaller. The loadout facility shall be constructed with sufficient surface area, using curbs or other means, to prevent a release from the facility; and002.04 After June 27, 2011 new, or modified, loadout facilities must be constructed to have curbs or berms to prevent external stormwater from draining into the loadout facility.198 Neb. Admin. Code, ch. 6, § 002
Amended effective 12/10/2019Amended effective 4/25/2020