_________________________________________________________________
Lower Frequency limit of measuring system, Hertz (Hz) (+3dB) | Maximum level in decibels (dB) |
0.1 Hz or lower - flat response ......................................... | 134 peak. |
2 Hz or lower - flat response ............................................ | 133 peak. |
6 Hz or lower - flat response ............................................ | 129 peak. |
C-weighted, slow response ............................................. | 105 peak dBC. |
If necessary to prevent damage based upon the consultant's report, the department shall specify lower maximum allowable airblast levels than those above.
_________________________________________________________________
_________________________________________________________________________________________
Distance (D) from the blasting site, in feet | Maximum allowable peak particle velocity (V max) for ground vibration, in inches/second | Scaled-distance factor to be applied without seismic monitoring (Ds) |
0 to 300 | 1.25 | 50 |
301 to 5,000 | 1.00 | 55 |
5,001 and beyond | 0.75 | 65 |
__________________________________________________________________________________________
W=(D/Ds) 2 where W=the maximum weight of explosives, in pounds, that can be detonated in any eight-millisecond period; D=the distance, in feet, from the blast to the nearest public building or structure, dwelling, school, church, or commercial or institutional building or structure, except as noted in (l); and Ds=the scaled distance factor, using the values identified in (k).
Mont. Admin. r. 17.24.159
AUTH: 82-4-321, MCA; IMP: 82-4-356, MCA