19 Miss. Code. R. 7-7.11

Current through December 10, 2024
Rule 19-7-7.11 - [Effective until 1/1/2025] Compliance Standards for Sale of Burglar Bars

Any burglar bars offered for sale or installation to the public in the state of Mississippi shall meet the following minimum specifications in the International Code Council (ICC), Chapter 3, Section R310 Emergency Escape and Rescue Openings and incorporated in the Mississippi Code as stated below.

R310.1Emergency escape and rescue opening required.

Basements, habitable attics and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way.

Exception: Storm shelters and basements used only to house mechanical equipment not exceeding a total floor area of 200 square feet (18.58 m).

R310.1.1Operational constraints and opening control devices.

Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools or special knowledge. Window opening control devices complying with ASTM F 2090 shall be permitted for use on windows serving as a required emergency escape and rescue opening.

R310.2Emergency escape and rescue openings.

Emergency escape and rescue openings shall have minimum dimensions as specified in this section.

R310.2.1Minimum opening area.

Emergency and escape rescue openings shall have a net clear opening of not less than 5.7 square feet (0.530 m). The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. The net clear height opening shall be not less than 24 inches (610 mm) and the net clear width shall be not less than 20 inches (508 mm).

Exception: Grade floor or below grade openings shall have a net clear opening of not less than 5 square feet (0.465 m).

R310.4Bars, grilles, covers and screens.

Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided that the minimum net clear opening size complies with Sections R310.1.1 to R310.2.3, and such devices shall be releasable or removable from the inside without the use of a key, tool, special knowledge or force greater than that required for the normal operation of the escape and rescue opening.

19 Miss. Code. R. 7-7.11

Miss. Code §§ 45-11-71 and 45-11-73 (Supp. 2018)
Amended 2/1/2017
Amended 1/1/2020