15 Miss. Code. R. 18-77-5.7.10

Current through December 10, 2024
Rule 15-18-77-5.7.10 - Minimum Specifications for the Spray Field
1. Spray irrigation systems may not be installed in drain ways, swamps, marshes, floodplain, concave landscape positions or other areas which would be prohibited.
2. Treated effluent shall be sprayed evenly over the entire spray field area with non overlapping patterns. The spray field shall consist of a minimum of three (3) spray heads.
3. The effluent distribution system shall be designed, constructed and maintained to provide for even distribution of effluent throughout the spray field.
4. Surface runoff of sprayed effluent from the spray field area shall not be permitted. Rainwater shall be diverted away from the spray field area.
5. The spray field area shall be designed and operated to prevent surface accumulation of sprayed effluent.
6. In order to prevent entrapped air causing serious problems pipelines shall be routed on contour, downhill or even uphill but not up and downhill along the same section of pipe.
7. The size of the spray field area shall be determined by soil texture and slope of the site to be sprayed (See Table 1).

Table I - SIZING - Spray Irrigation

Results of the Soil and Site Evaluation

Soil Textural Class

Ribbon Lengths (Inches)

EPA Manual Application Rate

GPD/Ft 2

Absorption Area in Ft 2/Bedroom

Additional Absorption Area Over 2 Persons Per Bedroom

Slope

Slope

0 to 8 %

9 to 12%

13 to 16%

0 to 8 %

9 to 12%

13 to 16%

Gravel

NOT SUITABLE

Coarse and Medium Sand

Fine and Loamy Sand

Sandy Loam

<0.5

1.2

0.8

0.6

694

928

1,040

347

478

520

Loam

Silt Loam

Sandy Clay Loam

<0.5 - 1.0

< 0.5- 1.0

1.0 - 2.0

0.45

1387

1734

2323

694

867

1162

Silt Clay Loam Clay Loam Sandy Clay

1.0 - 2.0

1.0 - 2.0

>2.0

0.2 - 0.3

0.2 - 0.3

-

2782

4637

6951

1391

2319

3476

Silty Clay Clay

>2.0

-

6951

8693

11588

3476

4347

5794

Table II FILL MATERIAL

Seasonal High Water Table Depth (inches)

... with a Restrictive Horizon/Layer (inches)

... without a Restrictive Horizon/Layer (inches)

0

6

12

1

5

11

2

4

10

3

3

9

4

2

8

5

1

7

6

-

6

7

-

5

8

-

4

9

-

3

10

-

2

11

-

1

12

-

-

Figure I SPRAY IRRIGATION SYSTEM

Click Here To View Image

Figure II FLEX TUBE/SWING JOINT ASSEMBLY

Click Here To View Image

15 Miss. Code. R. 18-77-5.7.10

Miss Code Ann. § 41-67-3