15 Miss. Code. R. 18-77-5.6.9

Current through December 10, 2024
Rule 15-18-77-5.6.9 - Existing System

In addition to the visual inspection conducted by the Environmentalist the following will apply:

1. The system must be inspected by a Certified Installer that is manufacturer's authorized representative to verify that the Subsurface Drip Irrigation System is functioning.
2. The manufacturer's authorized representative must furnish written verification, to the Department, that an inspection was made.

Figure I - Subsurface Drip Irrigation System (Example Sketch Only)

Click Here To View Image

Table I - SIZING - Drip Irrigation

Results of the Soil and Site Evaluation

Soil Textural Class

Loading Rate GPD/

Ft 2

Lf Per Bedroom

Additional Lf/Person Over 2 Person Per

Depth of Drip Line in Inches

Gravel

NOT SUITABLE

Coarse Sand

0.5

130

65

6-18

Medium Sand

0.5

130

65

6-18

Fine Sand

0.5

130

65

6-18

Loamy Sand

0.5

130

65

6-18

Sandy Loam

0.3

217

109

6-18

Light Loam

0.3

217

109

6-18

Heavy Loam

0.3

217

109

6-18

Silt Loam

0.3

217

109

6-18

Sandy Clay Loam

0.3

217

109

6-18

Light Clay Loam

0.15

434

217

6-18

Heavy Clay Loam

0.15

434

217

6-18

Light Silty Clay Loam

0.15

434

217

6-18

Heavy Silty Clay Loam

0.15

434

217

6-18

Sandy Clay

0.15

434

217

6-18

Silty Clay

0.05

1300

650

6-18

Clay

0.05

1300

650

6-18

Table II - SETBACK REQUIREMENTS FROM SENSITIVE WATER (Minimum Distance from the Water Edge)

Soil Textural Class

Slope of Less Than 8 Percent

Slope of More Than 8 Percent

Gravel

NOT APPLICABLE

Coarse Sand

100 feet

100 feet

Medium Sand

100 feet

100 feet

Fine Sand

100 feet

100 feet

Loamy Sand

100 feet

100 feet

Sandy Loam

100 feet

100 feet

Light Loam

50 feet

100 feet

Heavy Loam

50 feet

100 feet

Silt Loam

50 feet

100 feet

Sandy Clay Loam

50 feet

100 feet

Light Clay Loam

50 feet

100 feet

Heavy Clay Loam

50 feet

100 feet

Light Silty Clay Loam

50 feet

100 feet

Heavy Silty Clay

50 feet

100 feet

Sandy Clay

100 feet

100 feet

Silty Clay

100 feet

100 feet

Clay

100 feet

100 feet

Table III - Subsurface Drip Irrigation Pump Cycles (Minimum Requirements)

Pump Cycles/24 Hours

Gallons Pumped/Bedroom/Cycle

Additional Gallons Pumped Per Person Over 2 Per Bedroom

6

25

12.5

8

18.75

9.375

10

15

7.5

12

12.5

6.25

15 Miss. Code. R. 18-77-5.6.9

Miss Code Ann. § 41-67-3