Current through December 10, 2024
Rule 15-18-77-3.2.12 - Sanitary Conveniences1.Toilet and Shower Facilitiesa. Comfort stations shall be provided at one or more locations in every recreational vehicle campground. They shall be convenient of access and shall be located within 500 feet from any campsite not provided with water and sewer connections. b. If facilities for both males and females are housed within the same structure, they shall be separated and appropriately marked. c. All doors to the exterior shall open outward, be self-closing, and shall be screened by means of a vestibule or wall to prevent direct view of the interior when the exterior doors are open. Such screening shall not be required on single unit toilet buildings. d. The interior finish of walls shall be moisture resistant for their entire height to facilitate washing and cleaning. e. The floors shall be constructed of material impervious to water and shall be easily cleanable. A floor drain shall be provided in the toilet room. f. All rooms shall be adequately lighted and well ventilated, with all openings effectively screened. g. Facilities shall be provided to adequately supply hot water to all showers and lavatories during times of peak demand. 2.Number, Location and Arrangement of Toilets, Urinals, Lavatories, and Showersa. All recreational vehicle campgrounds shall be provided with flush toilets. Recreational Vehicle Lodging Parks accepting only self-contained units are exempt from providing toilet and bathhouse accommodations. b. Facilities shall be provided as follows: i. A minimum of 1 toilet, 1 lavatory, and 1 shower for each sex shall be provided for each 15 unsewered campsites up to the first 30 such campsites. For each additional thirty unsewered sites or less, an additional toilet, lavatory, and shower shall be provided for each sex. ii. A minimum of 1 toilet, 1 lavatory and 1 shower for each sex shall be provided for each 50 sewered campsites. iii. In recreational vehicle campgrounds, urinals shall be substituted for one-third of the toilets required in the men's facilities. Only individual stalls or wall-hung urinals shall be acceptable. c. Each toilet shall be in a separate compartment and shall be provided with a door with a latch for privacy and a holder or dispenser for toilet paper. Dividing walls or partitions shall be at least 5 feet high and shall be separated from the floor by a space not greater than 18 inches. d. Toilet compartments shall not be less than 30 inches in width and there shall be not less than 30 inches of clear space in front of each toilet. 3.Showers:a. Each shower provided shall be of the individual type, be screened from view, and be not less than 36 inches by 36 inches in area. Each shower area shall be designed to minimize the flow of water into the dressing area and shall be properly connected to the sewerage system by means of a trapped inlet. b. A dressing area, equivalent to a minimum of 9 square feet per shower, shall be provided. Each dressing area shall be equipped with a minimum of two clothing hooks per shower. c. The floors of showers and dressing areas shall have an impervious skid resistant surface. 15 Miss. Code. R. 18-77-3.2.12