Minn. R. agency 175, ch. 8820, EXHIBITS, FIGURES, AND TABLES, pt. 8820.9956

Current through Register Vol. 49, No. 24, December 9, 2024
Part 8820.9956 - MINIMUM VERTICAL CLEARANCES FOR UNDERPASSES

Underpass projects must meet or exceed the minimum dimensions indicated in the following design chart.

Rural-Suburban Design, Vertical ClearanceUrban Design, Vertical Clearance
(feet-inches)(feet-inches)
Highway under Roadway Bridge16-414-6
Highway under Railroad Bridge16-414-6
Highway under Pedestrian Bridge17-415-6 (a)
Highway under Sign Structure17-415-6 (a)
Railroad under Roadway Bridge (b)22-022-0

(a) For replacement of skyway structures, the minimum clearance over traveled way is the existing structure clear height.
(b) Variances to the required minimum may be granted by the commissioner of transportation. That approval eliminates the need for a state-aid variance.

Minn. R. agency 175, ch. 8820, EXHIBITS, FIGURES, AND TABLES, pt. 8820.9956

20 SR 1041; 23 SR 1455; L 1998 c 403 s 29; 24 SR 1885; 29 SR 449

Statutory Authority: MS s 162.02; 162.09