Current through Register Vol. 49, No. 24, December 9, 2024
Part 4761.2625 - ABRASIVE AND WATER BLASTING METHODS FOR LEAD HAZARD REDUCTIONA. Abrasive blasting and water blasting are prohibited except as provided in items B and C.B. Exterior water blasting, abrasive blasting, wet abrasive blasting, modified-wet abrasive blasting, and vacuum blasting must be performed:(1) in compliance with parts 4761.2650 and 7025.0010 to 7025.0080; and(2) in a manner that prevents water and debris from leaving the property and that provides for filtration of dust and debris from any water.C. Interior abrasive blasting and modified-wet abrasive blasting are allowed only: (1) on radiators and other metal building components if the work area is totally enclosed during the blasting according to part 4761.2645; and(2) in masonry or stone basements if the work is conducted according to part 4761.2645.Minn. R. agency 144, ch. 4761, LEAD STANDARDS; METHODS, pt. 4761.2625
Statutory Authority: MS s 144.9508