Current through Register Vol. 49, No. 24, December 9, 2024
Part 4725.5150 - WATER-SUPPLY WELL SUCTION LINESubpart 1.Construction.As specified in UPC section 604.1 as incorporated by part 4714.0050, a suction line for a water-supply well must be constructed of:
B. galvanized iron or steel;D. plastic pipe. For well water irrigation systems, aluminum pipe may also be used.
Subp. 2.Extensions.A suction line extending outside the well casing must be protected by being:
A. fully exposed in a building as specified in part 4725.2175;B. fully exposed above the established ground surface; orC. installed within an outer, concentric pipe with the annular space between the pipes filled with water from the system and maintained at system pressure.Subp. 3.Exception.An unprotected suction line may be installed below the established ground surface for an irrigation well if the well is:
A. located in an agricultural field;B. installed in an unconfined aquifer in unconsolidated material; andC. used for a manifold collection system under negative pressure.Minn. R. agency 144, ch. 4725, WATER-SUPPLY WELLS, pt. 4725.5150
17 SR 2773; 33 SR 211; 45 SR 986Statutory Authority: MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13