An elevator boring must be constructed according to the general construction standards in parts 4725.2010 to 4725.3875 and cased, sealed, and maintained according to this chapter to prevent the vertical movement of water.
The boring must be cased to the bottom of the excavation.
The boring is exempt from the requirements in parts 4725.2150; 4725.2175; 4725.2185; 4725.2250, subpart 8, concerning extension of the casing 12 inches above the established ground surface; and 4725.2250, subpart 11.
Hydraulic fluid must be protected from leakage by:
In addition to the requirements of part 4725.3750, when a hydraulic cylinder is removed from an elevator boring for repair or replacement, the boring must be protected from hydraulic fluid leakage according to subpart 4.
An elevator boring which is unsuccessful or no longer in use must be sealed according to part 4725.3850. The hydraulic cylinder, debris or obstructions, and sand placed around the hydraulic cylinder must be removed prior to sealing.
Minn. R. agency 144, ch. 4725, MONITORING WELLS, pt. 4725.7250
Statutory Authority: MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13