Current through Vol. 24-21, December 1, 2024
Section R. 460.732 - Annual report contentsRule 32. The annual report of an electric utility or cooperative made pursuant to these rules must contain all of the following information:
(a) The meter reading factor. If the meter reading factor is less than 95%, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(b) The new service installation factor. If the new service installation factor is less than 90% completed within 15 business days, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(c) The wire-down relief factor. If the wire-down relief factor is less than 90% within 120 minutes within metropolitan statistical areas or less than 90% within 180 minutes in non-metropolitan statistical areas, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(d) The service restoration factor for all conditions. If the service restoration factor for all conditions is less than 90% of customers restored within 36 hours or less, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(e) The service restoration factor for normal conditions. If the service restoration factor for normal conditions is less than 90% of customers restored within 8 hours or less, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(f) The service restoration factor for gray sky conditions. If the service restoration factor for gray sky conditions is less than 90% of customers restored within 24 hours or less, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(g) The service restoration factor for catastrophic conditions. If the service restoration factor for catastrophic conditions is less than 90% of customers restored within 48 hours or less, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level.(h) CEMI4. All of the following information:(i) The number of customers that experienced 4 or more sustained interruptions.(ii) If more than 6% of customers experienced 4 or more sustained interruptions within the year, and that year was 2029 or a prior year, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level, including a description of all catastrophic conditions experienced during the year.(iii) If more than 5% of customers experienced 4 or more sustained interruptions within the year, and that year was 2030 or a future year, then the report must contain a detailed explanation of the steps that the electric utility or cooperative is taking to bring its performance to an acceptable level, including a description of all catastrophic conditions experienced during the year.(i) The number and total dollar amount of all customer credits the electric utility or cooperative provided during the year, broken down by customer class, for its failure to restore service to customers within 96 hours of the start of a sustained interruption that occurred during the course of catastrophic conditions.(j) The number and total dollar amount of all customer credits the electric utility or cooperative provided during the year, broken down by customer class, for its failure to restore service to customers within 48 hours of the start of a sustained interruption that occurred during the course of gray sky conditions.(k) The number and total dollar amount of all customer credits the electric utility or cooperative provided during the year, broken down by customer class, for its failure to restore service to customers within 16 hours of the start of a sustained interruption that occurred during normal conditions.(l) The number and total dollar amount of all customer credits the electric utility or cooperative provided during the year, broken down by customer class, to individual customers who experienced 6 or more sustained interruptions.(m) For each electric utility with 1,000,000 or more customers, a list of its 10 worst performing circuits for the prior year in terms of SAIDI and SAIFI.(n) For each electric utility or cooperative with less than 1,000,000 customers, a list of the worst performing 1% of circuits for the prior year in terms of SAIDI and SAIFI.(o) For each of the worst performing circuits listed in subrules (m) or (n) of this rule, the electric utility or cooperative shall provide all of the following information: (i) SAIDI and SAIFI for the year.(ii) Circuit name, number, and location.(iii) Length of circuit in miles.(iv) Number of customers served.(vii) List of outages and causes.(viii) Corrective action to improve performance.(p) Number of CEMI reporting for indices CEMI0 through CEMI10+.(q) Number of CELID reporting for indices CELID8hours, CELID24hours, CELID48hours.(r) Number of non-residential customers experiencing momentary interruptions.(s) A summary table indicating whether the electric utility or cooperative complied or failed to comply with each of the standards established by these rules.Mich. Admin. Code R. 460.732
2004 AACS.; 2023 MR 7, Eff. 4/10/2023