Section R. 400.11303 - Light, ventilation, and screening

Rule 303.

(1) A camp shall ensure that every sleeping room that is occupied by campers is constructed as follows:
(a) Has natural light that is from a source which is equal to an area that is not less than 8% of the floor area of the room.
(b) Has total operable window area that is not less than 45% of the required window area, unless mechanical ventilation is provided. A camp shall not count a skylight, louver, transom, glass-blocked panel, or similar light-transmitting device for more than 50% of the required area in place of conventional windows, screened areas, and glazed doors.
(2) A camp shall supply screens for each door, window, and other opening to the outside that is used for ventilation of a building occupied by campers for the control of flying insects. A screen door shall swing outward and have a self-closing device that is in working condition.
(3) A camp shall ensure that all openings into tents are screened for insect control or, as an alternative, that personal protective netting is made available to campers.