Mich. Admin. Code R. 408.18124

Current through Vol. 24-22, December 15, 2024
Section R. 408.18124 - Mechanical dumpbins and blenders

Rule 8124.

(1) An opening in a mechanical dumpbin or blender shall be guarded by 1 of the following:
(a) Parallel bars not more than 3 inches apart on centers.
(b) Not less than 11-gauge wire mesh with openings not more than 3 inches in any direction. If an employee can reach the moving parts of the machine through the guard, then the 3-inch opening shall be reduced until the hazard is eliminated.
(2) A mechanical dumpbin and blender shall be equipped with a suction type dust hood of such capacity as to prevent dust circulation outside the hood.
(3) Where the loading point of a manually filled mechanical dumpbin is more than 24 inches above the floor, a bag rest shall be provided.
(4) A hinged dumpbin cover shall be provided with a means to lock the cover in the open position or shall be counterbalanced so that it cannot accidentally fall down while the dumpbin is in operation.

Mich. Admin. Code R. 408.18124

1979 AC; 1982 AACS