Current through Vol. 24-22, December 15, 2024
Section R. 408.11716 - Hoisting cables and chainsRule 1716.
(1) A chain and its component parts, other than alloy steel chain having a minimum tensile strength of 125,000 pounds per square inch, shall have a designed safety factor of not less than 5. Alloy chain shall not be used in excess of the working load in straight tension for its size as prescribed in table 1.(2) A hoist cable and its component parts for mobile refuse packer units shall have a designed safety factor of not less than 2 based on the applied pull.(3) A hoist cable shall be inspected on installation and monthly thereafter.(4) A hoist cable shall not be used if, in any length equal to 8 diameters of the cable, the total number of visible broken wires exceeds 10% of the total number of wires, or if the cable shows other signs of excessive wear, corrosion, kinks or bird caging.(5) Where a "U" type cable clamp or clip is applied, it shall comply with table 2.(6) The hydraulic relief valve in a cable operating system shall be set at the manufacturer's rating and sealed.Mich. Admin. Code R. 408.11716