Current through Vol. 24-21, December 1, 2024
Section R. 325.10720d - Enhanced treatment for Cryptosporidium; developing disinfection profile and benchmarkRule 720d.
(1) Subpart H supplies required to develop disinfection profiles under R 325.10720c shall follow the requirements of this rule. These Subpart H supplies are also considered "supplies" in this rule. Supplies shall monitor under subrule (2) of this rule to determine the total log inactivation for Giardia lamblia and viruses. Supplies shall determine log inactivation for Giardia lamblia through the entire plant, based on the protocol in R 325.10722(3)(b). Supplies shall determine log inactivation for viruses through the entire treatment plant, based on the protocol in R 325.10722(3)(c).(2) Subpart H supplies with a single point of disinfectant application before the entrance to the distribution system shall conduct the monitoring in R 325.10722(3)(a). Supplies with more than 1 point of disinfectant application shall conduct the monitoring in R 325.10722(3)(a) for each disinfection segment. Subpart H supplies shall monitor the parameters necessary to determine the total inactivation ratio.(3) Instead of conducting new monitoring under subrule (2) of this rule, Subpart H supplies may elect to meet the requirements of either of the following: (a) Supplies that have at least 1 year of existing data that are substantially equivalent to data collected under R 325.10722(3)(a) to meet the requirements of subule (2) of this rule may use these data to develop disinfection profiles as specified in this rule if the supply has neither made a significant change to its treatment practice nor changed sources since the data were collected. Supplies may develop disinfection profiles using up to 3 years of existing data.(b) Supplies may use a disinfection profile or profiles developed under R 325.10722 instead of developing a new profile if the supply has neither made a significant change to its treatment practice nor changed sources since the profile was developed. Supplies that have not developed a virus profile under R 325.10722 shall develop a virus profile using the same monitoring data on which the Giardia lamblia profile is based.(4) Subpart H supplies shall calculate the total inactivation ratio for Giardia lamblia using the protocol in R 325.10722(3)(b). Supplies shall calculate the log of inactivation for viruses using the protocol in R 325.10722(3)(c).(5) Subpart H supplies shall use the procedures in R 325.10722(4)(c) to calculate a disinfection benchmark.Mich. Admin. Code R. 325.10720d
2009 AACS; 2015 MR 20, Eff. 10/16/2015