Rule 610a.
Where:
VOCtot = Total volatile organic compound content of all coating, as applied, on an occurrence weighted average basis, and used to determine compliance with this paragraph.
i = subscript denoting a specific coating applied.
n = Total number of coatings applied in the final repair operation, other than clear coatings
VOCcc = The volatile organic compound content, as applied, of the clear coat used in the final repair operation.
VOCi = The volatile organic compound content of each coating used in the final repair operation, as applied, other than clear coatings.
TABLE 64-a
Volatile organic compound emission limits for existing automobile and light-duty truck coating lines and miscellaneous materials used at automobile and light-duty truck assembly coating facilities.
Coating Category | VOC Emission Limit | ||
Prime-electrodeposition process (EDP) (including application area, spray/rinse stations, and curing oven) | When solids turnover ratio (RT)>=0.16: | When 0.040<=RT<=0.160: | When RT<=0.040: |
0.71 | (0.084 x 3500.160-RT x 8.34)1 | No VOC emission limit. | |
Primer surfacer4 (including application area, flash-off area, and oven) | 12.02 | ||
Topcoat (including application area, flash-off area, and oven) | 12.02 | ||
Final repair operations | 4.83 | ||
Combined primer-surfacer and topcoat | 12.02 | ||
Miscellaneous Materials Used at Automobile and Light-Duty Truck Assembly Coating Facilities | |||
Coating Category | lb VOC/gal coating (minus water, as applied) | g VOC/L of coating (minus water and exempt compounds, as applied) | |
Glass Bonding Primer5 | 7.53 | 900 | |
Adhesive5 | 2.13 | 250 | |
Cavity Wax5 | 5.43 | 650 | |
Sealer5 | 5.43 | 650 | |
Deadener5 | 5.43 | 650 | |
Gasket/Gasket sealing material5 | 1.73 | 200 | |
Underbody Coating5 | 5.43 | 650 | |
Trunk interior coating5 | 5.43 | 650 | |
Bedliner5 | 1.73 | 200 | |
Weatherstrip adhesive5 | 6.33 | 750 | |
Lubricating wax/compound5 | 5.83 | 700 |
1 Pounds of volatile organic compounds per gallon of applied coating solids.
2 Pounds of volatile organic compounds per gallon of applied coating solids on a daily weighted average basis as determined by following the procedures in the "Protocol for determining the Daily Volatile Organic Compound Emission Rate of Automobile and Light-Duty Truck Topcoat Operations" (EPA-453/R-08-002).
3 Pounds of volatile organic compounds per gallon of coating, minus water, as applied.
4 The primer surfacer or topcoat coating category would include an anti-chip, blackout, or spot primer coating if this coating is applied as part of the primer surfacer or topcoat coating operation.
5 VOC emission limits must not be applied to materials supplied in containers with a net volume of 16 ounces or less, or a net weight of 1 pound or less.
TABLE 64-b
Volatile organic compound emission limits for existing metal furniture coating lines.
Coating Type | Column A1 | Column B2 | ||
Bake d | Air Dried | Baked | Air Dried | |
General, 1 Component | 2.3 | 2.3 | 3.3 | 3.3 |
General, Multi-Component | 2.3 | 2.8 | 3.3. | 4.5 |
Extreme High Gloss | 3.0 | 2.8 | 5.1 | 4.5 |
Extreme Performance | 3.0 | 3.5 | 5.1 | 6.7 |
Heat Resistant | 3.0 | 3.5 | 5.1 | 6.7 |
Metallic | 3.5 | 3.5 | 6.7 | 6.7 |
Pretreatment Coatings | 3.5 | 3.5 | 6.7 | 6.7 |
Solar Absorbent | 3.0 | 3.5 | 5.1 | 6.7 |
1 Pounds of volatile organic compounds emitted per gallon of coating, minus water, as applied.
2 Pounds of volatile organic compounds emitted per gallon of applied coating solids. The purpose of column B emission limits is to allow credit for transfer efficiencies greater than the baseline transfer efficiency. Note: department approval under R 336.1602(2) of the transfer efficiency test method is required.
TABLE 64-c
Volatile organic compound emission limits for existing cans, coils, fabrics, and insulation of magnet wire coating lines.
Coating Category | Column A1 |
Coating of cans | |
Sheet basecoat (exterior and interior) and overvarnish; 2-piece Can exterior (basecoat and overvarnish) | 2.8 |
2- and 3-piece can interior body spray; 2-piece can interior end (spray or roll coat) | 4.2 |
3-piece can side-seam | 5.5 |
End sealing compound | 3.7 |
Coating of coils | 2.6 |
Coating of fabric | 2.9 |
Insulation of magnet wire | 1.7 |
1 Pounds of volatile organic compounds emitted per gallon of coating, minus water, as applied.
TABLE 64-d
Volatile organic compound emission limits for paper, film, and foil surface coating and pressure sensitive tape and label surface coating.
Coating Category | Column A1 | Column B2 |
Paper, Film, and Foils Surface Coating (not including pressure sensitive type and label) | 0.08 | 0.40 |
Pressure Sensitive Tape and Label Surface Coating | 0.067 | 0.20 |
1 Pounds of volatile organic compounds emitted per gallon of coating, minus water, as applied.
2 Pounds of volatile organic compounds emitted per gallon of applied coating solids. The purpose of column B emission limits is to allow credit for transfer efficiencies greater than the baseline transfer efficiency. Note: department approval of the transfer efficiency test method is required.
Mich. Admin. Code R. 336.1610a