Rule 430.
HOURLY RATE (lbs SO2/hour) = [COG (1000 ft3/hour) * (0.702 lbs SO2 / 1000 ft3) + BFG (ft3/hr) * H2S (gr/ft3 BFG) * (1 lb H2S / 7,000 gr H2S) * (1.88 lb SO2 /lb H2S) + NG (1,000,000 ft3/hr)* (0.6 lb SO2 / 1,000,000 ft3)]
Where:
HOURLY RATE = boiler house group or furnace group emission rate (lbs SO2/hour).
COG = actual volume of coke oven gas consumed (1000 ft3 per clock-hour) in a furnace group or boiler house group.
BFG = actual volume of blast furnace gas consumed (ft3 per clock-hour) in a furnace group or boiler house group.
NG = actual volume of natural gas consumed (1,000,000 ft3 per clock-hour) in a furnace group or boiler house group.
H2S = actual concentration of hydrogen sulfide in BFG (gr/ft3) determined on a 1-hour average basis for each clock-hour of operation.
Mich. Admin. Code R. 336.1430