Current through Vol. 24-21, December 1, 2024
Section R. 336.2176 - Data reduction procedures for sulfuric acid plantRule 1176. The owner or operator of a sulfuric acid plant that is subject to the provisions of this part shall do both of the following:
(a) Establish a conversion factor 3 times daily according to the procedures in the standards of performance for new stationary sources, 40 C.F.R. Part 60.84(b), adopted by reference in R 336.1299.(b) Multiply the conversion factor by the average sulfur dioxide concentration in the flue gases to obtain the average sulfur dioxide emissions in pounds per short ton.Mich. Admin. Code R. 336.2176
1980 AACS; 1989 AACS; 2014 AACS