Rule 1031. Reference test method 9B, coke oven inspection procedures for visible emissions, reads as follows:
(number of doors with visible emissions | |
on operating ovens in the battery) x 100 = | actual percentage of |
[(number of doors on total ovens in the battery) - (number of doors obstructed from view on operating ovens)] | doors with visible emissions |
(number of charging ports with visible emissions on operating ovens in the battery) x 100 = (number of doors obstructed from view on operating ovens)] | actual percentage of charging ports with visible emissions |
(number of standpipe assembly emission points with = visible emissions on operating ovens) x 100 (number of standpipe assembly emission points on the operating ovens of the coke battery) | actual percentage of charging ports with visible emissions |
Mich. Admin. Code R. 336.2031