Md. Code Regs. 11.04.14.03

Current through Register Vol. 51, No. 25, December 13, 2024
Section 11.04.14.03 - Minimum Yellow Change Intervals
A. On any approach to a traffic signal where a traffic control monitoring system is in use, the agency shall ensure that the yellow change interval on that approach is not shorter in duration than that determined by the formula set forth in §B of this regulation, following any adjustments required by §C of this regulation.
B. Formula. The formula for calculating the yellow change interval (in seconds) is:

Y = 1.0 + ((0.733 X S)/(D + (0.32 X G)))

Where:

Y = yellow change interval (in seconds);

S = approach speed (in miles per hour);

D = deceleration rate (in ft/sec2);

G = approach grade (in percent).

C. Adjustments to Calculated Yellow Change Interval.
(1) The calculated yellow change interval shall be rounded up to the nearest half second.
(2) If the calculated yellow change interval is less than 3.0 seconds, then the yellow change interval shall be 3.0 seconds.
(3) If the calculated yellow change interval is greater than 6.0 seconds, then the yellow change interval shall be 6.0 seconds.

Md. Code Regs. 11.04.14.03

Regulations .03 adopted as an emergency provision effective April 1, 2004 (31:11 Md. R. 855); adopted permanently effective September 27, 2004 (31:19 Md. R. 1433)