The following additions, insertions, deletions, and other changes are hereby made to the 2015 International Building Code:
Delete [NAME OF JURISDICTION]; and
Insert "State of Maine" in its place.
Delete "International Fuel Gas Code"; and
Insert "NFPA 54 National Fuel Gas Code: Fire safety codes and standards adopted pursuant to Title 25 M.R.S §§2452 and 2465 " in its place.
Delete Section 101.4.2 "Mechanical" in its entirety, without substitution.
Delete "International Plumbing Code"; and
Insert "Maine State Plumbing Code, adopted pursuant to Title 32, M.R.S § 3404- B" in its place.
Delete "International Private Sewage Disposal Codes"; and
Insert "Maine State Plumbing Code, adopted pursuant to Title 32, M.R.S § 3404- B" in its place.
Delete Section 101.4.4 "Property maintenance" in its entirety, without substitution.
Delete "International Fire Code"; and
Insert "NFPA #1; Fire codes and standards adopted pursuant to Title 25 M.R.S. §§2452 and 2465 " in its place.
Insert "No provisions of the MUBEC shall be construed to prohibit the adoption or enforcement of an ordinance of any political subdivision that sets forth provisions for local enforcement of building codes. Such ordinances may include items such as, permits, permit fees, boards of appeals and violations."
Delete Section 102.4.1
Delete section 102.4.2
Delete "International Property Maintenance Code or the International Fire Code"; and
Insert "NFPA #1; Fire Safety codes and standards adopted pursuant to Title 25 M.R.S §§2452 and 2465 " in its place.
Delete "International Property Maintenance Code or the International Fire Code"; and
Insert "NFPA #1; Fire Safety codes and standards adopted pursuant to Title 25 M.R.S §§2452 and 2465 " in its place.
Delete Section 103 "Department of Building Safety" in its entirety, without substitution.
Delete all language in Section 104.8; and
Insert "See 14 MRSA §8101 " in its place.
Insert "where required by municipal ordinance" at the end of the paragraph.
Insert "Structures exempt from permits shall be located in compliance with zoning and floodplain regulations" at the end of the paragraph.
Delete Section 109 "Fees" in its entirety, without substitution.
Delete Section 113 "Board of Appeals" and Section 114 "Violations" in their entirety, without substitution.
Delete All language in section 308.3.3; and
Insert "See NFPA 101 2015 edition chapter 16"
Delete All language in section 308.6; and
Insert "See NFPA 101 2015 edition Chapter 16"
Delete "A child day care facility that provides care for more than five but not more than 100 children 2 1/2 years or less of age" and
Insert "A child day care facility that provides care for more than twelve but not more than 100 children 2 1/2 years or less of age."
Delete Section 308.5.2 and the exceptions thereto, in its entirety, without substitution.
Delete all language in Section 404.6; and
Insert "See NFPA 101 8.6.7 (2015 edition)" in its place.
Delete this section: "and an automatic sprinkler system in accordance with Section 903.2.8 "
602.1.2 Alternative Provisions. As an alternative to the construction types defined in 602.2 through 602.5, buildings and structures erected or to be erected, altered or extended in height or area may be classified as construction type IV-A, IV-B or IV-C in accordance with Chapter 6 of the 2021 International Building Code. Buildings and structures classified as IV-A, IV-B or IV-C shall comply with all provisions of the 2021 International Building Code specific to mass timber and the construction type of the building or structure, as well as all other applicable provisions of this code, including provisions for buildings of Type IV construction.
Insert a new Section 716.5.9.1.2 to read: "Every door assembly in a stair enclosure serving more than four (4) stories shall permit re-entry from the enclosure to the interior of the building. Exception: An automatic release that is actuated with the initiation of the building fire alarm or fire detection system shall be provided to unlock all stair enclosure door assemblies to allow re-entry."
Delete "and smoke" in the first sentence.
Delete "100" and Insert "300"
Insert Exception: An automatic sprinkler system shall not be required in Group R-2 and R-3 occupancies if all of the following conditions are met:
Insert"and any other adopted standard of the Office of the State Fire Marshal and in accordance with the sprinkler rules in the Office of The State Fire Marshal fire sprinkler technical policy"
Delete "Exception: Where approved by the building official, the actual number of occupants for whom each occupied space, floor or building is designed, although less than those determined by calculation, shall be permitted to be used in the determination of the design occupant load."
Insert (within the paragraph; after) The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less than the total occupant load served by the means of egress multiplied by 0.3 inches (7.61mm) per occupant for stairways.
Exception: Board and Care 0.4; Health Care - Sprinkled 0.3; Health Care Non-sprinkled 0.6.
Delete "and by 0.2 inches (5.08 mm) per occupant for other egress components"
Insert The total width of means of egress in inches (mm) shall not be less than the total occupant load served by the means of egress multiplied by 0.2 inches (5.08 mm) per occupant for other egress components.
Exception: Board and Care 0.2; Health Care Sprinkled 0.2; Health Care Non-Sprinkled 0.5.
Delete "E" from the Group reference in two (2) locations in the first paragraph.
Delete all language in Section 1017;and
Insert "See NFPA 101-2009 Table A7.6" in its place.
Insert "I-1" in the occupancy column as a new row; and
Insert "See NFPA 101-2009 Table A7.6"
Delete "E" from the occupancy column as one of the use groups; and
Insert a new row in the column titled "Single Use"; and
Insert "E" in the Single Use occupancy column; and
Insert "150" in the without sprinkler system (feet) column; and
Insert "200" in the sprinkling system (feet) column.
Delete "S-1 and S-2" from the occupancy column; and
Insert "S-1 and S-2" in the occupancy column as a new row; and
Insert "See NFPA 101-2009 Table A7.6"
Insert "the means of escape shall be continuously maintained free of all obstructions or impediments to full use in case of fire or other emergency"
[M] 2801.1 Scope. Mechanical appliances, equipment and systems shall be constructed, installed and maintained in accordance and
Delete "with the International Mechanical Code and the International Fuel Gas Code. Masonry chimneys, fireplaces and barbecues shall comply with the International Mechanical Code and Chapter 21 of this code." and
Insert "with ASHRAE 62.1 201 6 edition"