06- 096 C.M.R. ch. 104, § 2

Current through 2024-51, December 18, 2024
Section 096-104-2 - Emission Standard

No person shall emit or cause to be emitted any particulate air contaminants from:

A. Any incinerator darker than a number 1 on the Ringelmann Chart, excluding the emission of water vapor;
B. Any Class III, IV, V, VI, and VII incinerator having a designed charging rate of 50 tons per day or less, that exceed 0.2 grains per standard cubic foot of dry flue gas for a two hour sampling period corrected to 12 percent carbon dioxide without the contribution of carbon dioxide from the auxiliary fuel.
C. Any class incinerator having a designed charging rate greater than 50 tons per day, that exceed 0.08 grains per standard cubic foot of dry flue gas for a 2-hour sampling period, corrected to 12 percent carbon dioxide without the contribution of carbon dioxide from the auxiliary fuel.

06- 096 C.M.R. ch. 104, § 2