La. Admin. Code tit. 51 § XVII-305

Current through Register Vol. 50, No. 11, November 20, 2024
Section XVII-305 - Space and Lighting Requirements for Classrooms [formerly paragraph 17:025]
A. In all schools, and in other special types of institutions with classrooms, a minimum of 20 square feet of floor space shall be provided in every classroom for each student.
B. [Formerly paragraph 17:026] In all schools, and in other special types of institutions with classrooms, artificial lighting shall be provided in all classrooms and other rooms with the minimum level of illumination as listed in Table 305.B below.

Table 305.B-School/Classroom Lighting

Room Type Classification

Direct Lighting Footcandle Levels (1)

Indirect Footcandle Levels (2)

Maximum

Average

Minimum

Maximum

Average

Minimum

Administrative Areas

Offices/Receptionist

75

50

25

60

40

20

Storage Rooms

38

25

13

38

25

13

Restrooms

38

25

13

38

25

13

Conference/Resource Rooms

75

50

25

60

40

20

Healthcare Area

75

50

25

60

40

20

Teacher Prep/Work Area

75

50

25

60

40

20

Classrooms

General Classrooms

75

50

25

60

40

20

Visual Arts Rooms

75

50

25

60

40

20

Modular Technology Labs

75

50

25

60

40

20

Computer Aided/Drafting Labs

45

30

15

45

30

15

Industrial Arts Rooms

90

60

30

90

60

30

Computer Labs

60

40

20

60

40

20

Graphics Labs

75

50

25

60

40

20

Life Skills Labs

75

50

25

75

50

25

Science Rooms/Labs

75

50

25

75

50

25

Laundry Rooms

38

25

13

38

25

13

Music Rooms

75

50

25

60

40

20

Large Group Instruction Rooms

75

50

25

60

40

20

Media Center

Active Areas

75

50

25

60

40

20

Inactive Areas

60

40

20

60

40

20

Student Dining/Auditoriums

Assembly

30

20

10

N/A

Stage/Work Lights

30

20

10

N/A

Makeup/Dressing Rooms

75

50

25

75

50

25

Theatrical Control Room

45

30

15

45

30

15

Kitchen

60

40

20

N/A

Dining Areas

60

40

20

60

40

20

Athletic Areas

Gymnasium-Elementary School

75

50

25

N/A

Gymnasium-Middle School

75

50

25

N/A

Gymnasium-High School

90

60

30

N/A

Multi-use Physical Education Rooms

75

50

25

N/A

Locker Rooms

38

25

13

38

25

13

Circulation

Hallways

30

20

10

30

20

10

Stairwells

30

20

10

30

20

10

Maintenance Areas

Custodial Closets

45

30

15

45

30

15

Mechanical Rooms

45

30

15

45

30

15

Footnotes to Table 305.B

(1) Direct lighting refers to light that is being directed in a downward direction towards the surface being illuminated.

(2) Indirect lighting refers to light that is directed at least partially in an upward direction or is reflected in some manner towards the surface being illuminated.

1. General Notes on Lighting System Design and Enforcement of Table 305.B
a. For design in new and significantly renovated schools, the designer shall utilize the Illuminating Engineering Society of North America (IESNA) Lighting Handbook; however, the standards contained in Table 305B of this Part shall control if there is a conflict.
b. Enforcement of the lighting standards is based upon the average illumination level in each room or area.
c. For instructional spaces utilizing digital "smart boards" or outfitted for audio-visual presentations, the designer should consider the installation of lighting controls readily accessible to the instructor having capability to reduce the illumination on the screen to seven footcandles or less, while maintaining an average of 20 footcandles within the remaining functional areas of the room or area.
d. For instructional spaces utilizing dry-erase whiteboards, the designer should consider the installation of separately controlled, dedicated luminaries mounted parallel to the whiteboard, providing 30 footcandles average on the vertical plane of the whiteboard.

La. Admin. Code tit. 51, § XVII-305

Promulgated by the Department of Health and Hospitals, Office of Public Health, LR 28:1391 (June 2002), amended LR 37:2167 (July 2011).
AUTHORITY NOTE: Promulgated in accordance with R.S. 40:4(A)(10) and R.S. 40:5(2)(3)(4)(5)(16)(17)(19)(21).