Current through Register Vol. 50, No. 11, November 20, 2024
Section XIV-935 - Vent HeadersA. Stack vents and vent stacks may be connected into a common vent header at the top of the stacks and then terminate as required by this Chapter. This header shall be sized in accordance with the requirements of Table 937.B of this code, the number of units being the sum of all units on all stacks connected thereto, and the developed length being the longest vent length from the intersection at the base of the most distant stack to the vent terminal as a direct extension of one stack.La. Admin. Code tit. 51, § XIV-935
Promulgated by the Department of Health and Hospitals, Office of Public Health, LR 38:2866 (November 2012).AUTHORITY NOTE: Promulgated in accordance with R.S. 40:4(A)(7) and R.S. 40:5(2)(3)(7)(9)(16)(17)(20).