La. Admin. Code tit. 43 § XIII-2111

Current through Register Vol. 50, No. 11, November 20, 2024
Section XIII-2111 - External Corrosion Control: Examination of Buried Pipeline When Exposed [49 CFR 192.459]
A. Whenever an operator has knowledge that any portion of a buried pipeline is exposed, the exposed portion must be examined for evidence of external corrosion if the pipe is bare, or if the coating is deteriorated. If external corrosion requiring remedial action under §2135 is found, the operator shall investigate circumferentially and longitudinally beyond the exposed portion (by visual examination, indirect method, or both) to determine whether additional corrosion requiring remedial action exists in the vicinity of the exposed portion. [ 49 CFR 192.459]

La. Admin. Code tit. 43, § XIII-2111

Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:235 (April 1983), amended LR 10:528 (July 1984), LR 27:1544 (September 2001), LR 30:1253 (June 2004).